Elevator emergency calling system

IC2 is a simple and cheap way to get intercom between machine room and the lift car. Typical use is to comply with EN81 in hydraulic lifts where there is no acoustical connection between the lift shaft and the machine room. Also suitable or lifts with shaft heights exceeding 30 meters or in cases where an intercom is requested.

Main features


◼︎ Connect existing emergency telephones

◼︎ Supply voltage 12VDC or 24VDC ◼︎ Call any SafeLine unit connected to the same telephoneline ◼︎ Use any standard analogue handset with DTMF formachine room ◼︎ Call is automatically disconnected after 5 minutes
Data sheet
Citation
EN81-28/EN81-70
Operating voltage
12VDC or 24VDC
Operating current
Max.50mA
Communication mode
PSTN
GSM communication
GL1
Extension
1 unit(MX2,TL1,TL6)
External DTNF telephone
1
Talk time
5 minutes(terminated automatically)
Multiple connection mode
Parallel connection
Working temperature
-20 ... +60℃
Size
61 × 115 × 23mm

Public Information

Download public materials without logging in.

Corporate brochure

SUMMIT Product Summary V1.0
More related content

Emergency call system supporting accessories


In addition to designing and manufacturing the most advanced elevator emergency telephones, Summit also produces accessories that can be used in conjunction with these products. This includes: GSM voice and data communication unit, inductive hearing circuit, connection kit for easy replacement of OEM telephone products, emergency power supply unit, etc.